Compare commits

..

3 commits

Author SHA1 Message Date
b5c9e36c29
Prefix global variables 2025-06-19 10:21:03 +02:00
8864518c39
Customize it to fit the hardware. 2025-06-05 15:39:05 +02:00
3db798de59
clang-format 2025-05-14 22:51:42 +02:00
2 changed files with 149 additions and 128 deletions

View file

@ -3,24 +3,23 @@ UseTab: Never
IndentWidth: 4
TabWidth: 4
BreakBeforeBraces: Custom
AllowShortFunctionsOnASingleLine: Inline
AllowShortBlocksOnASingleLine: false
AllowShortFunctionsOnASingleLine: InlineOnly
AllowShortIfStatementsOnASingleLine: false
AllowShortLambdasOnASingleLine: true
AllowAllArgumentsOnNextLine: true
IndentCaseLabels: true
AccessModifierOffset: -4
NamespaceIndentation: None
NamespaceIndentation: All
FixNamespaceComments: false
PackConstructorInitializers: Never
AlignAfterOpenBracket: AlwaysBreak
BreakConstructorInitializersBeforeComma: true
InsertBraces: true
BraceWrapping:
AfterClass: true # false
AfterControlStatement: false
AfterEnum: true # false
AfterFunction: true # false
AfterNamespace: false
AfterNamespace: true # false
AfterObjCDeclaration: true # false
AfterStruct: true # false
AfterUnion: true # false

View file

@ -45,132 +45,154 @@ typedef enum OpenThermMessageType // old name OpenThermRequestType; // for backw
OT_UNKNOWN_DATA_ID = 0b111
} open_therm_message_type_t;
// clang-format off
typedef enum OpenThermMessageID
{
MSG_ID_STATUS = 0, // flag8/flag8 |R-| Master and Slave Status flags.
MSG_ID_T_SET = 1, // f8.8 |-W| Control Setpoint i.e.CH water temperature Setpoint(°C)
MSG_ID_M_CONFIG_M_MEMEBER_ID_CODE = 2, // flag8/u8 |-W| Master Configuration Flags / Master MemberID Code
MSG_ID_S_CONFIG_S_MEMEBER_ID_CODE = 3, // flag8/u8 |R-| Slave Configuration Flags / Slave MemberID Code
MSG_ID_REMOTE_REQUEST = 4, // u8/u8 |-W| Remote Request
MSG_ID_ASF_FLAGS = 5, // flag8/u8 |R-| Application - specific fault flags and OEM fault code
// bit: description [ clear/0, set/1]
// 0: Service request [service not reqd, service required]
// 1: Lockout-reset [ remote reset disabled, rr enabled]
// 2: Low water press [no WP fault, water pressure fault]
// 3: Gas/flame fault [ no G/F fault, gas/flame fault ]
// 4: Air press fault [ no AP fault, air pressure fault ]
// 5: Water over-temp[ no OvT fault, over-temperat. Fault]
// 6: reserved
// 7: reserved
// OEM diagnostic code
//
MSG_ID_RBP_FLAGS = 6, // flag8/flag8 |R-| Remote boiler parameter transfer - enable & read / write flags
MSG_ID_COOLING_CONTROL = 7, // f8.8 |R-| Cooling control signal(%)
MSG_ID_T_SET_CH2 = 8, // f8.8 |-W| Control Setpoint for 2e CH circuit(°C)
MSG_ID_TR_OVERRIDE = 9, // f8.8 |R-| Remote override room Setpoint
MSG_ID_TSP = 10, // u8/u8 |R-| Number of Transparent - Slave - Parameters supported by slave
MSG_ID_TSP_INDEX_TSP_VALUE = 11, // u8/u8 |RW| Index number / Value of referred - to transparent slave parameter.
MSG_ID_FHB_SIZE = 12, // u8/u8 |R-| Size of Fault - History - Buffer supported by slave
MSG_ID_FHB_INDEX_FHB_VALUE = 13, // u8/u8 |R-| Index number / Value of referred - to fault - history buffer entry.
MSG_ID_MAX_REL_MOD_LEVEL_SETTING = 14, // f8.8 |W-| Maximum relative modulation level setting(%)
MSG_ID_MAX_CAPACITY_MIN_MOD_LEVEL = 15, // u8/u8 |R-| Maximum boiler capacity(kW) / Minimum boiler modulation level(%)
MSG_ID_TR_SET = 16, // f8.8 |-W| Room Setpoint(°C)
MSG_ID_REL_MOD_LEVEL = 17, // f8.8 |R-| Relative Modulation Level(%)
MSG_ID_CH_PRESSURE = 18, // f8.8 |R-| Water pressure in CH circuit(bar)
MSG_ID_DHW_FLOW_RATE = 19, // f8.8 |R-| Water flow rate in DHW circuit. (litres / minute)
MSG_ID_DAY_TIME = 20, // special/u8 |RW| Day of Week and Time of
// HB : bits 7,6,5 : day of week bits 4,3,2,1,0 : hours LB : minutes
MSG_ID_DATE = 21, // u8/u8 |RW| Calendar date
MSG_ID_YEAR = 22, // u16 |RW| Calendar year
MSG_ID_TR_SET_CH2 = 23, // f8.8 |-W| Room Setpoint for 2nd CH circuit(°C)
MSG_ID_TR = 24, // f8.8 |-W| Room temperature(°C)
MSG_ID_TBOILER = 25, // f8.8 |R-| Boiler flow water temperature(°C)
MSG_ID_TDHW = 26, // f8.8 |R-| DHW temperature(°C)
MSG_ID_TOUTSIDE = 27, // f8.8 |R-| Outside temperature(°C)
MSG_ID_TRET = 28, // f8.8 |R-| Return water temperature(°C)
MSG_ID_TSTORAGE = 29, // f8.8 |R-| Solar storage temperature(°C)
MSG_ID_TCOLLECTOR = 30, // f8.8 |R-| Solar collector temperature(°C)
MSG_ID_T_FLOW_CH2 = 31, // f8.8 |R-| Flow water temperature CH2 circuit(°C)
MSG_ID_TDHW2 = 32, // f8.8 |R-| Domestic hot water temperature 2 (°C)
MSG_ID_TEXHAUST = 33, // s16 |R-| Boiler exhaust temperature(°C)
//
MSG_ID_TBOILER_HEAT_EEXCHANGER = 34, // f8.8 |??| Boiler heat exchanger temperature(°C)
MSG_ID_BOILER_FAN_SSPEED_SETPOINT_AND_ACTIAL = 35, // u8/u8 |??| Boiler fan speed Setpoint and actual value
MSG_ID_FLAME_CURRENT = 36, // f8.8 |??| Electrical current through burner flame[μA]
MSG_ID_TR_CH2 = 37, // f8.8 |??| Room temperature for 2nd CH circuit(°C)
MSG_ID_RELATIVE_HUMIDITY = 38, // f8.8 |??| Actual relative humidity as a percentage
MSG_ID_TR_OOVERRIDE2 = 39, // f8.8 |??| Remote Override Room Setpoint 2
//
MSG_ID_TDHW_SET_UBT_DHW_SET_LB = 48, // s8/s8 |R-| DHW Setpoint upper & lower bounds for adjustment(°C)
MSG_ID_MAX_TSET_UB_MAX_TSET_LB = 49, // s8/s8 |R-| Max CH water Setpoint upper & lower bounds for adjustment(°C)
MSG_ID_OTC_HEAT_CURVE_UL_BOUNDS = 50, // s8/s8 |R-| OTC heat curve ratio upper & lower bounds for adjustment
MSG_ID_TDHW_SET = 56, // f8.8 |RW| DHW Setpoint(°C) (Remote parameter 1)
MSG_ID_MAX_TSET = 57, // f8.8 |RW| Max CH water Setpoint(°C) (Remote parameters 2)
MSG_ID_OTC_CURVE_RATIO = 58, // f8.8 |RW| OTC heat curve ratio (°C) (Remote parameter 3)
//
MSG_ID_STATUS_VENTILATION_HEAT_RECOVERY = 70, // flag8/flag8 |??| Master and Slave Status flags ventilation / heat - recovery
MSG_ID_VSET = 71, // -/u8 |??| Relative ventilation position (0-100%). 0% is the minimum set ventilation and 100% is the maximum set ventilation.
MSG_ID_ASF_FLAGS_OEM_FAULT_CODE_VENTILATION_HEAT_RECOVERY = 72, // flag8/u8 |??| Application-specific fault flags and OEM fault code ventilation / heat-recovery
MSG_ID_OEM_DDIAGNOSTIC_CODE_VENTILATION_HEAT_RECOVERY = 73, // u16 |??| An OEM-specific diagnostic/service code for ventilation / heat-recovery system
MSG_ID_S_CONFIG_S_MEMEBER_ID_CODE_VENTILATION_HEAT_RECOVERY = 74, // flag8/u8 |??| Slave Configuration Flags / Slave MemberID Code ventilation / heat-recovery
MSG_ID_OPENTHERM_VVERSION_VENTILATION_HEAT_RECOVERY = 75, // f8.8 |??| The implemented version of the OpenTherm Protocol Specification in the ventilation / heat-recovery system.
MSG_ID_VENTILATION_HEAT_RECOVERY_VERSION = 76, // u8/u8 |??| Ventilation / heat-recovery product version number and type
MSG_ID_REL_VENT_LEVEL = 77, // -/u8 |??| Relative ventilation (0-100%)
MSG_ID_RH_EXHAUST = 78, // -/u8 |??| Relative humidity exhaust air (0-100%)
MSG_ID_CO2_EXHAUST = 79, // u16 |??| CO2 level exhaust air (0-2000 ppm)
MSG_ID_TSI = 80, // f8.8 |??| Supply inlet temperature (°C)
MSG_ID_TSO = 81, // f8.8 |??| Supply outlet temperature (°C)
MSG_ID_TEI = 82, // f8.8 |??| Exhaust inlet temperature (°C)
MSG_ID_TEO = 83, // f8.8 |??| Exhaust outlet temperature (°C)
MSG_ID_RPM_EXHAUST = 84, // u16 |??| Exhaust fan speed in rpm
MSG_ID_RPM_SUPPLY = 85, // u16 |??| Supply fan speed in rpm
MSG_ID_RBP_FLAGS_VENTILATION_HEAT_RECOVERY = 86, // flag8/flag8 |??| Remote ventilation / heat-recovery parameter transfer-enable & read/write flags
MSG_ID_NOMINAL_VENTILATION_VALUE = 87, // u8/- |??| Nominal relative value for ventilation (0-100 %)
MSG_ID_TSP_VENTILATION_HEAT_RECOVERY = 88, // u8/u8 |??| Number of Transparent-Slave-Parameters supported by TSPs ventilation / heat-recovery
MSG_ID_TSPindexTSP_VALUE_VENTILATION_HEAT_RECOVERY = 89, // u8/u8 |??| Index number / Value of referred-to transparent TSPs ventilation / heat-recovery parameter.
MSG_ID_FHB_SIZE_VENTILATION_HEAT_RECOVERY = 90, // u8/u8 |??| Size of Fault-History-Buffer supported by ventilation / heat-recovery
MSG_ID_FHB_INDEX_FHB_VALUE_VENTILATION_HEAT_RECOVERY = 91, // u8/u8 |??| Index number / Value of referred-to fault-history buffer entry ventilation / heat-recovery
MSG_ID_BRAND = 93, // u8/u8 |??| Index number of the character in the text string ASCII character referenced by the above index number
MSG_ID_BRAND_VERSION = 94, // u8/u8 |??| Index number of the character in the text string ASCII character referenced by the above index number
MSG_ID_BRAND_SERIAL_NUMBER = 95, // u8/u8 |??| Index number of the character in the text string ASCII character referenced by the above index number
MSG_ID_COOLING_OPERATION_HOURS = 96, // u16 |??| Number of hours that the slave is in Cooling Mode. Reset by zero is optional for slave
MSG_ID_POWER_CYCLES = 97, // u16 |??| Number of Power Cycles of a slave (wake-up after Reset), Reset by zero is optional for slave
MSG_ID_RF_SENSOR_STATUS_INFORMATION = 98, // special/special|??| For a specific RF sensor the RF strength and battery level is written
MSG_ID_REMOTE_OVERRIDE_OOPERATING_MODE_HEATING_DHW = 99, // special/special|??| Operating Mode HC1, HC2/ Operating Mode DHW
//
MSG_ID_REMOTE_OVERRIDE_FUNCTION = 100, // flag8/- |R-| Function of manual and program changes in master and remote room Setpoint
//
MSG_ID_STATUS_SOLAR_STORAGE = 101, // flag8/flag8 |??| Master and Slave Status flags Solar Storage
MSG_ID_ASF_FLAGS_OEMFAULT_CODE_SOLAR_STORAGE = 102, // flag8/u8 |??| Application-specific fault flags and OEM fault code Solar Storage
MSG_ID_S_CONFIG_S_MEMBER_ID_CODE_SOLAR_STORAGE = 103, // flag8/u8 |??| Slave Configuration Flags / Slave MemberID Code Solar Storage
MSG_ID_SOLAR_STORAGE_VERSION = 104, // u8/u8 |??| Solar Storage product version number and type
MSG_ID_TSP_SOLAR_SSTORAGE = 105, // u8/u8 |??| Number of Transparent - Slave - Parameters supported by TSPs Solar Storage
MSG_ID_TSP_INDEX_TSP_VALUE_SOLAR_STORAGE = 106, // u8/u8 |??| Index number / Value of referred - to transparent TSPs Solar Storage parameter.
MSG_ID_FHB_SIZE_SOLAR_STORAGE = 107, // u8/u8 |??| Size of Fault - History - Buffer supported by Solar Storage
MSG_ID_FHB_INDEX_FHB_VALUE_SOLAR_STORAGE = 108, // u8/u8 |??| Index number / Value of referred - to fault - history buffer entry Solar Storage
MSG_ID_ELECTRICITY_PRODUCER_STARTS = 109, // U16 |??| Number of start of the electricity producer.
MSG_ID_ELECTRICITY_PRODUCER_HOURS = 110, // U16 |??| Number of hours the electricity produces is in operation
MSG_ID_ELECTRICITY_PRODUCTION = 111, // U16 |??| Current electricity production in Watt.
MSG_ID_CUMULATIV_ELECTRICITY_PRODUCTION = 112, // U16 |??| Cumulative electricity production in KWh.
MSG_ID_UNSUCCESSFULL_BURNER_STARTS = 113, // u16 |??| Number of un - successful burner starts
MSG_ID_FLAME_SIGNAL_TOO_LOW_NUMBER = 114, // u16 |??| Number of times flame signal was too low
//
MSG_ID_OEM_DDIAGNOSTIC_CODE = 115, // u16 |R-| OEM - specific diagnostic / service code
MSG_ID_SUCESSFULL_BURNER_SSTARTS = 116, // u16 |RW| Number of succesful starts burner
MSG_ID_CH_PUMP_STARTS = 117, // u16 |RW| Number of starts CH pump
MSG_ID_DHW_PUPM_VALVE_STARTS = 118, // u16 |RW| Number of starts DHW pump / valve
MSG_ID_DHW_BURNER_STARTS = 119, // u16 |RW| Number of starts burner during DHW mode
MSG_ID_BURNER_OPERATION_HOURS = 120, // u16 |RW| Number of hours that burner is in operation(i.e.flame on)
MSG_ID_CH_PUMP_OPERATION_HOURS = 121, // u16 |RW| Number of hours that CH pump has been running
MSG_ID_DHW_PUMP_VALVE_OPERATION_HOURS = 122, // u16 |RW| Number of hours that DHW pump has been running or DHW valve has been opened
MSG_ID_DHW_BURNER_OOPERATION_HOURS = 123, // u16 |-W| Number of hours that burner is in operation during DHW mode
MSG_ID_OPENTERM_VERSION_MASTER = 124, // f8.8 |R-| The implemented version of the OpenTherm Protocol Specification in the master.
MSG_ID_OPENTERM_VERSION_SLAVE = 125, // f8.8 |-W| The implemented version of the OpenTherm Protocol Specification in the slave.
MSG_ID_MASTER_VERSION = 126, // u8/u8 |-W| Master product version number and type
MSG_ID_SLAVE_VERSION = 127, // u8/u8 |R-| Slave product version number and type
MSG_ID_STATUS = 0, // flag8/flag8 |R-| Master and Slave Status flags.
MSG_ID_T_SET = 1, // f8.8 |-W| Control Setpoint i.e.CH water temperature Setpoint(°C)
MSG_ID_M_CONFIG_M_MEMEBER_ID_CODE = 2, // flag8/u8 |-W| Master Configuration Flags / Master MemberID Code
MSG_ID_S_CONFIG_S_MEMEBER_ID_CODE = 3, // flag8/u8 |R-| Slave Configuration Flags / Slave MemberID Code
MSG_ID_REMOTE_REQUEST = 4, // u8/u8 |-W| Remote Request
MSG_ID_ASF_FLAGS = 5, // flag8/u8 |R-| Application - specific fault flags and OEM fault code
// bit: description [ clear/0, set/1]
// 0: Service request [service not reqd, service required]
// 1: Lockout-reset [ remote reset disabled, rr enabled]
// 2: Low water press [no WP fault, water pressure fault]
// 3: Gas/flame fault [ no G/F fault, gas/flame fault ]
// 4: Air press fault [ no AP fault, air pressure fault ]
// 5: Water over-temp[ no OvT fault, over-temperat. Fault]
// 6: reserved
// 7: reserved
// OEM diagnostic code
//
MSG_ID_RBP_FLAGS = 6, // flag8/flag8 |R-| Remote boiler parameter transfer - enable & read / write flags
MSG_ID_COOLING_CONTROL = 7, // f8.8 |R-| Cooling control signal(%)
MSG_ID_T_SET_CH2 = 8, // f8.8 |-W| Control Setpoint for 2e CH circuit(°C)
MSG_ID_TR_OVERRIDE = 9, // f8.8 |R-| Remote override room Setpoint
MSG_ID_TSP = 10, // u8/u8 |R-| Number of Transparent - Slave - Parameters supported by slave
MSG_ID_TSP_INDEX_TSP_VALUE = 11, // u8/u8 |RW| Index number / Value of referred - to transparent slave parameter.
MSG_ID_FHB_SIZE = 12, // u8/u8 |R-| Size of Fault - History - Buffer supported by slave
MSG_ID_FHB_INDEX_FHB_VALUE = 13, // u8/u8 |R-| Index number / Value of referred - to fault - history buffer entry.
MSG_ID_MAX_REL_MOD_LEVEL_SETTING = 14, // f8.8 |W-| Maximum relative modulation level setting(%)
MSG_ID_MAX_CAPACITY_MIN_MOD_LEVEL = 15, // u8/u8 |R-| Maximum boiler capacity(kW) / Minimum boiler modulation level(%)
MSG_ID_TR_SET = 16, // f8.8 |-W| Room Setpoint(°C)
MSG_ID_REL_MOD_LEVEL = 17, // f8.8 |R-| Relative Modulation Level(%)
MSG_ID_CH_PRESSURE = 18, // f8.8 |R-| Water pressure in CH circuit(bar)
MSG_ID_DHW_FLOW_RATE = 19, // f8.8 |R-| Water flow rate in DHW circuit. (litres / minute)
MSG_ID_DAY_TIME = 20, // special/u8 |RW| Day of Week and Time of
// HB : bits 7,6,5 : day of week bits 4,3,2,1,0 : hours LB : minutes
MSG_ID_DATE = 21, // u8/u8 |RW| Calendar date
MSG_ID_YEAR = 22, // u16 |RW| Calendar year
MSG_ID_TR_SET_CH2 = 23, // f8.8 |-W| Room Setpoint for 2nd CH circuit(°C)
MSG_ID_TR = 24, // f8.8 |-W| Room temperature(°C)
MSG_ID_TBOILER = 25, // f8.8 |R-| Boiler flow water temperature(°C)
MSG_ID_TDHW = 26, // f8.8 |R-| DHW temperature(°C)
MSG_ID_TOUTSIDE = 27, // f8.8 |R-| Outside temperature(°C)
MSG_ID_TRET = 28, // f8.8 |R-| Return water temperature(°C)
MSG_ID_TSTORAGE = 29, // f8.8 |R-| Solar storage temperature(°C)
MSG_ID_TCOLLECTOR = 30, // f8.8 |R-| Solar collector temperature(°C)
MSG_ID_T_FLOW_CH2 = 31, // f8.8 |R-| Flow water temperature CH2 circuit(°C)
MSG_ID_TDHW2 = 32, // f8.8 |R-| Domestic hot water temperature 2 (°C)
MSG_ID_TEXHAUST = 33, // s16 |R-| Boiler exhaust temperature(°C)
//
MSG_ID_TBOILER_HEAT_EEXCHANGER = 34, // f8.8 |??| Boiler heat exchanger temperature(°C)
MSG_ID_BOILER_FAN_SSPEED_SETPOINT_AND_ACTIAL = 35, // u8/u8 |??| Boiler fan speed Setpoint and actual value
MSG_ID_FLAME_CURRENT = 36, // f8.8 |??| Electrical current through burner flame[μA]
MSG_ID_TR_CH2 = 37, // f8.8 |??| Room temperature for 2nd CH circuit(°C)
MSG_ID_RELATIVE_HUMIDITY = 38, // f8.8 |??| Actual relative humidity as a percentage
MSG_ID_TR_OOVERRIDE2 = 39, // f8.8 |??| Remote Override Room Setpoint 2
//
MSG_ID_TDHW_SET_UBT_DHW_SET_LB = 48, // s8/s8 |R-| DHW Setpoint upper & lower bounds for adjustment(°C)
MSG_ID_MAX_TSET_UB_MAX_TSET_LB = 49, // s8/s8 |R-| Max CH water Setpoint upper & lower bounds for adjustment(°C)
MSG_ID_OTC_HEAT_CURVE_UL_BOUNDS = 50, // s8/s8 |R-| OTC heat curve ratio upper & lower bounds for adjustment
MSG_ID_TDHW_SET = 56, // f8.8 |RW| DHW Setpoint(°C) (Remote parameter 1)
MSG_ID_MAX_TSET = 57, // f8.8 |RW| Max CH water Setpoint(°C) (Remote parameters 2)
MSG_ID_OTC_CURVE_RATIO = 58, // f8.8 |RW| OTC heat curve ratio (°C) (Remote parameter 3)
//
MSG_ID_STATUS_VENTILATION_HEAT_RECOVERY = 70, // flag8/flag8 |??| Master and Slave Status flags ventilation / heat - recovery
MSG_ID_VSET = 71, // -/u8 |??| Relative ventilation position (0-100%). 0% is the minimum set ventilation and 100% is the
// maximum set ventilation.
MSG_ID_ASF_FLAGS_OEM_FAULT_CODE_VENTILATION_HEAT_RECOVERY =
72, // flag8/u8 |??| Application-specific fault flags and OEM fault code ventilation / heat-recovery
MSG_ID_OEM_DDIAGNOSTIC_CODE_VENTILATION_HEAT_RECOVERY =
73, // u16 |??| An OEM-specific diagnostic/service code for ventilation / heat-recovery system
MSG_ID_S_CONFIG_S_MEMEBER_ID_CODE_VENTILATION_HEAT_RECOVERY =
74, // flag8/u8 |??| Slave Configuration Flags / Slave MemberID Code ventilation / heat-recovery
MSG_ID_OPENTHERM_VVERSION_VENTILATION_HEAT_RECOVERY = 75, // f8.8 |??| The implemented version of the OpenTherm Protocol
// Specification in the ventilation / heat-recovery system.
MSG_ID_VENTILATION_HEAT_RECOVERY_VERSION = 76, // u8/u8 |??| Ventilation / heat-recovery product version number and type
MSG_ID_REL_VENT_LEVEL = 77, // -/u8 |??| Relative ventilation (0-100%)
MSG_ID_RH_EXHAUST = 78, // -/u8 |??| Relative humidity exhaust air (0-100%)
MSG_ID_CO2_EXHAUST = 79, // u16 |??| CO2 level exhaust air (0-2000 ppm)
MSG_ID_TSI = 80, // f8.8 |??| Supply inlet temperature (°C)
MSG_ID_TSO = 81, // f8.8 |??| Supply outlet temperature (°C)
MSG_ID_TEI = 82, // f8.8 |??| Exhaust inlet temperature (°C)
MSG_ID_TEO = 83, // f8.8 |??| Exhaust outlet temperature (°C)
MSG_ID_RPM_EXHAUST = 84, // u16 |??| Exhaust fan speed in rpm
MSG_ID_RPM_SUPPLY = 85, // u16 |??| Supply fan speed in rpm
MSG_ID_RBP_FLAGS_VENTILATION_HEAT_RECOVERY =
86, // flag8/flag8 |??| Remote ventilation / heat-recovery parameter transfer-enable & read/write flags
MSG_ID_NOMINAL_VENTILATION_VALUE = 87, // u8/- |??| Nominal relative value for ventilation (0-100 %)
MSG_ID_TSP_VENTILATION_HEAT_RECOVERY =
88, // u8/u8 |??| Number of Transparent-Slave-Parameters supported by TSPs ventilation / heat-recovery
MSG_ID_TSPindexTSP_VALUE_VENTILATION_HEAT_RECOVERY =
89, // u8/u8 |??| Index number / Value of referred-to transparent TSPs ventilation / heat-recovery parameter.
MSG_ID_FHB_SIZE_VENTILATION_HEAT_RECOVERY =
90, // u8/u8 |??| Size of Fault-History-Buffer supported by ventilation / heat-recovery
MSG_ID_FHB_INDEX_FHB_VALUE_VENTILATION_HEAT_RECOVERY =
91, // u8/u8 |??| Index number / Value of referred-to fault-history buffer entry ventilation / heat-recovery
MSG_ID_BRAND = 93, // u8/u8 |??| Index number of the character in the text string ASCII character referenced by the above
// index number
MSG_ID_BRAND_VERSION = 94, // u8/u8 |??| Index number of the character in the text string ASCII character referenced by
// the above index number
MSG_ID_BRAND_SERIAL_NUMBER = 95, // u8/u8 |??| Index number of the character in the text string ASCII character referenced
// by the above index number
MSG_ID_COOLING_OPERATION_HOURS =
96, // u16 |??| Number of hours that the slave is in Cooling Mode. Reset by zero is optional for slave
MSG_ID_POWER_CYCLES =
97, // u16 |??| Number of Power Cycles of a slave (wake-up after Reset), Reset by zero is optional for slave
MSG_ID_RF_SENSOR_STATUS_INFORMATION =
98, // special/special|??| For a specific RF sensor the RF strength and battery level is written
MSG_ID_REMOTE_OVERRIDE_OOPERATING_MODE_HEATING_DHW = 99, // special/special|??| Operating Mode HC1, HC2/ Operating Mode DHW
//
MSG_ID_REMOTE_OVERRIDE_FUNCTION =
100, // flag8/- |R-| Function of manual and program changes in master and remote room Setpoint
//
MSG_ID_STATUS_SOLAR_STORAGE = 101, // flag8/flag8 |??| Master and Slave Status flags Solar Storage
MSG_ID_ASF_FLAGS_OEMFAULT_CODE_SOLAR_STORAGE =
102, // flag8/u8 |??| Application-specific fault flags and OEM fault code Solar Storage
MSG_ID_S_CONFIG_S_MEMBER_ID_CODE_SOLAR_STORAGE =
103, // flag8/u8 |??| Slave Configuration Flags / Slave MemberID Code Solar Storage
MSG_ID_SOLAR_STORAGE_VERSION = 104, // u8/u8 |??| Solar Storage product version number and type
MSG_ID_TSP_SOLAR_SSTORAGE = 105, // u8/u8 |??| Number of Transparent - Slave - Parameters supported by TSPs Solar Storage
MSG_ID_TSP_INDEX_TSP_VALUE_SOLAR_STORAGE =
106, // u8/u8 |??| Index number / Value of referred - to transparent TSPs Solar Storage parameter.
MSG_ID_FHB_SIZE_SOLAR_STORAGE = 107, // u8/u8 |??| Size of Fault - History - Buffer supported by Solar Storage
MSG_ID_FHB_INDEX_FHB_VALUE_SOLAR_STORAGE =
108, // u8/u8 |??| Index number / Value of referred - to fault - history buffer entry Solar Storage
MSG_ID_ELECTRICITY_PRODUCER_STARTS = 109, // U16 |??| Number of start of the electricity producer.
MSG_ID_ELECTRICITY_PRODUCER_HOURS = 110, // U16 |??| Number of hours the electricity produces is in operation
MSG_ID_ELECTRICITY_PRODUCTION = 111, // U16 |??| Current electricity production in Watt.
MSG_ID_CUMULATIV_ELECTRICITY_PRODUCTION = 112, // U16 |??| Cumulative electricity production in KWh.
MSG_ID_UNSUCCESSFULL_BURNER_STARTS = 113, // u16 |??| Number of un - successful burner starts
MSG_ID_FLAME_SIGNAL_TOO_LOW_NUMBER = 114, // u16 |??| Number of times flame signal was too low
//
MSG_ID_OEM_DDIAGNOSTIC_CODE = 115, // u16 |R-| OEM - specific diagnostic / service code
MSG_ID_SUCESSFULL_BURNER_SSTARTS = 116, // u16 |RW| Number of succesful starts burner
MSG_ID_CH_PUMP_STARTS = 117, // u16 |RW| Number of starts CH pump
MSG_ID_DHW_PUPM_VALVE_STARTS = 118, // u16 |RW| Number of starts DHW pump / valve
MSG_ID_DHW_BURNER_STARTS = 119, // u16 |RW| Number of starts burner during DHW mode
MSG_ID_BURNER_OPERATION_HOURS = 120, // u16 |RW| Number of hours that burner is in operation(i.e.flame on)
MSG_ID_CH_PUMP_OPERATION_HOURS = 121, // u16 |RW| Number of hours that CH pump has been running
MSG_ID_DHW_PUMP_VALVE_OPERATION_HOURS =
122, // u16 |RW| Number of hours that DHW pump has been running or DHW valve has been opened
MSG_ID_DHW_BURNER_OOPERATION_HOURS = 123, // u16 |-W| Number of hours that burner is in operation during DHW mode
MSG_ID_OPENTERM_VERSION_MASTER =
124, // f8.8 |R-| The implemented version of the OpenTherm Protocol Specification in the master.
MSG_ID_OPENTERM_VERSION_SLAVE =
125, // f8.8 |-W| The implemented version of the OpenTherm Protocol Specification in the slave.
MSG_ID_MASTER_VERSION = 126, // u8/u8 |-W| Master product version number and type
MSG_ID_SLAVE_VERSION = 127, // u8/u8 |R-| Slave product version number and type
} open_therm_message_id_t;
// clang-format on
typedef enum OpenThermStatus
{